Low Voltage Rvv Electric Power Cable Security PVC Insulated Cable

Model NO.: RVV12*2.5
Material Shape: Round Wire
Certification: ISO9001, CE, CCC
Brand: Potel
OEM or ODM: Yes
Name: Rvv Copper Cable
Trademark: POTEL
Specification: 200m or as customer request
Origin: Nanchang
HS Code: 8544492100
Model NO.: RVV12*2.5
Material Shape: Round Wire
Certification: ISO9001, CE, CCC
Brand: Potel
OEM or ODM: Yes
Name: Rvv Copper Cable
Trademark: POTEL
Specification: 200m or as customer request
Origin: Nanchang
HS Code: 8544492100
Product Description:

Product application:
    This product is suitable for weak current equipment control, communication signal transmission, broadcasting and weak current equipment power supply lines. It's widely used in the installation of the control of the intercom monitoring and control of instrument building.

Product Features:
1.Long-term working temperature is allowed to not exceed 70ºC 
2.The temperature of cable laying cannot be lower than 0ºC
3.The working voltage is up to 300v AC and 500v DC.
4.The conductor is made of stranded copper wire with twisted wire.
5.Used for high mechanical protection requirements, frequently moving and bending situation.
6.Packing length: 100m/roll, 200m/roll or as customers' requires.

Application Standard: GB/T5023.5-2008

Technical Parameters:
                      60227IEC 52 RVV 300/300V copper core PVC insulated PVC sheathed flexible cable
Cores ×Standard section(mm2) Insulation thickness nominal value(mm) Sheath thickness nominal value(mm) Average form factor (mm) Maximum conductor resistance at 20ºCQ/km Insulation resistance minimum at 70ºC
(MΩ.km)
Lower limit Upper limit Copper core Tinned copper core
2x0.50 0.5 0.6 4.6
3.0x4.9
5.9
3.7x5.9
39 40.1 0.012
2x0.75 0.5 0.6 4.9
3.2x5.2
6.3
3.8x6.3
26 26.7 0.01
3x0.50 0.5 0.6 4.9 6.3 39 40.1 0.012
3x0.75 0.5 0.6 5.2 6.7 26 26.7 0.01
 
                60227IEC 53 RVV 300/500Vcopper core PVC insulated PVC sheathed flexible cable
 
Cores ×Standard section(mm2) Insulation thickness nominal value(mm)  Sheath thickness nominal value(mm) Average form factor (mm) Maximum conductor resistance at 20ºCQ/km Insulation resistance minimum at 70ºC
(MΩ.km)
Lower limit Upper limit Copper core Tinned copper core
2X0. 75 0.6 0.8 5.7
3.7x6.0
7.2
4.5x7.2
26 26.7 0.011
2x1 0.6 0.8 5.9
3.9x6.2
7.5
47x7.5
19.5 20 0.010
2x 1.5 0.7 0.8 6.8 8.6 13.3 13.7 0.010
2x2.5 0.8 1.0 8.4 10.6 7.98 8.21 0.009
3x0.75 0.6 0.8 6.0 7.6 26 26.7 0.011
3x1 0.6 0.8 6.3 8.0 19.5 20 0.010
3 x 1.5 0.7 0.9 7.4 9.4 13.3 13.7 0.010
3x2.5 0.8 1.1 9.2 11.4 7.98 8.21 0.009
4x0.75 0.6 0.8 6.6 8.3 26 26.7 0.011
4x1 0.6 0.9 7.1 9.0 19.5 20 0.010
4x 1.5 0.7 1.0 8.4 10.5 13.3 13.7 0.010
4X2.5 0.8 1.1 10.1 12.5 7.98 8.21 0.009
5 x 0.75 0.6 0.9 7.4 9.3 26 26.7 0.011
5x1 0.6 0.9 7.8 9.8 19.5 20 0.010
5x 1.5 0.7 1.1 9.3 11.6 13.3 13.7 0.010
5x 2.5 0.8 1.2 11.2 13.9 7.98 8.21 0.009


Certificate:
Low Voltage Rvv Electric Power Cable Security PVC Insulated Cable


Package:
Low Voltage Rvv Electric Power Cable Security PVC Insulated Cable
Product Description:

Product application:
    This product is suitable for weak current equipment control, communication signal transmission, broadcasting and weak current equipment power supply lines. It's widely used in the installation of the control of the intercom monitoring and control of instrument building.

Product Features:
1.Long-term working temperature is allowed to not exceed 70ºC 
2.The temperature of cable laying cannot be lower than 0ºC
3.The working voltage is up to 300v AC and 500v DC.
4.The conductor is made of stranded copper wire with twisted wire.
5.Used for high mechanical protection requirements, frequently moving and bending situation.
6.Packing length: 100m/roll, 200m/roll or as customers' requires.

Application Standard: GB/T5023.5-2008

Technical Parameters:
                      60227IEC 52 RVV 300/300V copper core PVC insulated PVC sheathed flexible cable
Cores ×Standard section(mm2) Insulation thickness nominal value(mm) Sheath thickness nominal value(mm) Average form factor (mm) Maximum conductor resistance at 20ºCQ/km Insulation resistance minimum at 70ºC
(MΩ.km)
Lower limit Upper limit Copper core Tinned copper core
2x0.50 0.5 0.6 4.6
3.0x4.9
5.9
3.7x5.9
39 40.1 0.012
2x0.75 0.5 0.6 4.9
3.2x5.2
6.3
3.8x6.3
26 26.7 0.01
3x0.50 0.5 0.6 4.9 6.3 39 40.1 0.012
3x0.75 0.5 0.6 5.2 6.7 26 26.7 0.01
 
                60227IEC 53 RVV 300/500Vcopper core PVC insulated PVC sheathed flexible cable
 
Cores ×Standard section(mm2) Insulation thickness nominal value(mm)  Sheath thickness nominal value(mm) Average form factor (mm) Maximum conductor resistance at 20ºCQ/km Insulation resistance minimum at 70ºC
(MΩ.km)
Lower limit Upper limit Copper core Tinned copper core
2X0. 75 0.6 0.8 5.7
3.7x6.0
7.2
4.5x7.2
26 26.7 0.011
2x1 0.6 0.8 5.9
3.9x6.2
7.5
47x7.5
19.5 20 0.010
2x 1.5 0.7 0.8 6.8 8.6 13.3 13.7 0.010
2x2.5 0.8 1.0 8.4 10.6 7.98 8.21 0.009
3x0.75 0.6 0.8 6.0 7.6 26 26.7 0.011
3x1 0.6 0.8 6.3 8.0 19.5 20 0.010
3 x 1.5 0.7 0.9 7.4 9.4 13.3 13.7 0.010
3x2.5 0.8 1.1 9.2 11.4 7.98 8.21 0.009
4x0.75 0.6 0.8 6.6 8.3 26 26.7 0.011