Quadruplex PVC Drop Urd Power XLPE Electric Aluminum ABC Cable

Model NO.: ABC cable
Material Shape: Round Wire
Range of Application: Overhead / Underground
Certification: ISO9001, CE, CCC, VDE
ABC Cable: 6AWG, 4AWG, 2AWG, 1/0AWG, 2/0AWG, 4/0AWG
Trademark: JIUSHUI
Transport Package: Coil / Drum
Specification: CE ISO ICEA SABS ASTM
Origin: China
Model NO.: ABC cable
Material Shape: Round Wire
Range of Application: Overhead / Underground
Certification: ISO9001, CE, CCC, VDE
ABC Cable: 6AWG, 4AWG, 2AWG, 1/0AWG, 2/0AWG, 4/0AWG
Trademark: JIUSHUI
Transport Package: Coil / Drum
Specification: CE ISO ICEA SABS ASTM
Origin: China

Specifications
 
Quadruplex Service Drop Aluminum Conductors ACSR Neutral-Messenger, A cable factory in China,Since 1984 
400 staff,12,000 m2 


 
pplications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201 alloy. One conductor is manufactured with an extruded ridge for phase identification.

Standards
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474. 

Note : 
Designated sizes are : ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for 6201.Conductor temperature of 90°C for XLR 75°C for Poly; ambient temperatures of 40°C; emissivity 0.9; 2ft./sec/wind in sun. To determine current ampacity by conductor size, please consult The National Electric Code, latest edition

Quadruplex PVC Drop Urd Power XLPE Electric Aluminum ABC Cable
Quadruplex PVC Drop Urd Power XLPE Electric Aluminum ABC Cable
Quadruplex PVC Drop Urd Power XLPE Electric Aluminum ABC Cable
 
Specifications
 
Quadruplex Service Drop Aluminum Conductors ACSR Neutral-Messenger, A cable factory in China,Since 1984 
400 staff,12,000 m2 


 
pplications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201 alloy. One conductor is manufactured with an extruded ridge for phase identification.

Standards
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474. 

Note : 
Designated sizes are : ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for 6201.Conductor temperature of 90°C for XLR 75°C for Poly; ambient temperatures of 40°C; emissivity 0.9; 2ft./sec/wind in sun. To determine current ampacity by conductor size, please consult The National Electric Code, latest edition

Quadruplex PVC Drop Urd Power XLPE Electric Aluminum ABC Cable
Quadruplex PVC Drop Urd Power XLPE Electric Aluminum ABC Cable
Quadruplex PVC Drop Urd Power XLPE Electric Aluminum ABC Cable
 

Ethernet Switch

Test items
The performance indicators are tested using a dedicated Ethernet test instrument, and the test results of these performance indicators can also evaluate whether the LAN system meets the acceptance requirements. From GBT21671-2008 "Ethernet-based LAN System Acceptance Evaluation Specification", it can be understood that LAN can also judge performance by measuring performance indicators such as network throughput, transmission delay, and packet loss rate. The Ethernet tester is a rugged test platform suitable for field use. It has a complete Ethernet test function, dual optical ports and dual electrical ports, Ethernet service interface module, HST-3000 supports multiple data stream tests. Including 10/100/1000M Ethernet link traffic generation and troubleshooting, it can test electrical and optical port links up to 1Gbit/s. Due to the limitation of various conditions in the acceptance inspection, point-to-point or routing network testing can be supported for routine testing of switches.
The problem
The overall characteristics of modern test instruments are high reliability, high performance and high applicability. Therefore, the gap between domestic test products and foreign products is reflected in this aspect. Although some domestic testing equipment is close to the international advanced level in certain performance indicators, there are generally few products with comprehensive equipment performance indicators that meet international standards. In addition, most of the domestic test instruments are common specifications, which cannot meet the test work in some special environments. Low-level automated testing is also a common problem. [3]
Switch test technology
Nowadays, switches put forward new requirements on the performance of switches based on application requirements. There have been new developments in comprehensive network services, security, and intelligence. Protocol testing is a basic switch testing technology. The network protocol is to improve the efficiency of testing and the effectiveness of communication to ensure the rules of communication. In the era of increasing network communication, network protocols are also indispensable. The basic requirements of network protocols are correct functions, good interoperability and superior performance. The initial prototype of protocol testing is software testing, and the main categories are black box testing, white box testing and gray box testing.

Ethernet Switch,Web Management Switch,Non-Web Management Switch,Reverse Power Switch,10G Switch,Combo Port

Shenzhen GL-COM Technology CO.,LTD. , https://www.szglcom.com

Posted on